Single Phase Motor

Single Phase Motor

iconiconiconiconicon

The structure of 1-phase asynchronous motors consists of two basic components, stator, and rotor, as in 3-phase asynchronous motors. Stator is the fixed part of the motor. Stator has a stator core and field windings. In the stator of 1-phase asynchronous motors, there are usually two windings as main and auxiliary windings.



Product Details

Rotor is the rotating part of the motor. There is wind in the rotors of the slip-ring asynchronous motors, and short-circuited bars in the rotor of the squirrel-cage asynchronous motors. The industrial asynchronous motor product range of Volt Motor consists of squirrel-cage asynchronous motors.

motor
motor

In asynchronous motors, the frequency of the rotating field created in the air gap and the rotation frequency of the rotor are not the same. These motors are called asynchronous for this reason. The frequency of the rotating field in the air gap depends on the motor’s feed frequency and the number of poles and does not change with the motor’s load, but the rotation frequency of the rotor varies according to the load. As the load increases in the motor operation area, the motor rotation speed decreases, and the motor rotation speed increases as the load decreases. The motor rotation speed is the highest in idle mode. The motor rotation speed of the asynchronous motor in the motor operation area cannot exceed the rotation speed of the rotating field. The rotation speed of the rotating field is calculated as follows:

N = 120 * F / P

  • N: rotation speed of rotating field [rpm]
  • f: feed frequency [Hz]
  • P: number of poles of stator winding

As is seen here, the rotating field speed of a 2-pole motor will be 3000rpm and the rotating field speed of a 4-pole motor will be 1500rpm. The change in the rotation speed of the asynchronous motor at different loads can be seen in the torque-speed graph shown below. In order for the generation of start-up moments in one-phase asynchronous motors, alternating currents of different phases from the main and auxiliary windings must pass. A series capacitor is connected to the auxiliary winding circuit to provide this. In this way, a two-phase motor occurs. In addition to the permanent capacitor, a start-up capacitor that will be activated only during the start-up and deactivated with a mechanism when the start-up is completed can also be used to increase the motor start-up moment. In order to deactivate the start-up capacitor, the centrifugal switch is used in the mono-phase products of the volt motor. Volt Motor 1-phase asynchronous motor types; Permanent Circuit Capacitor Motors: These motors have only permanent circuit capacitors. The permanent circuit capacitor is active both during the motor’s start-up and operation. Start-up and Permanent Circuit Capacitor Motors: These motors also have a start-up capacitor in addition to a permanent circuit capacitor. The start-up capacitor is only activated during start-up and is deactivated by the centrifugal switch after the motor was operated. The permanent circuit capacitor is active both when the motor is started and when it is operating. Single-phase asynchronous motors; can be used directly by operating from the network (DOL). Standard motors can only be used in 50Hz or only 60Hz networks. Standard motors can be operated by supplying 220 V residential networks.

Related Product

Dynamic Motor

Dynamic Motor

Dynamic Motors strives to find you the best deals in the pre-owned vehicle market. As a company, we have years of experience and expertise.

Read more
Dynamic RO Membrane

Dynamic RO Membrane

There are many applications for RO, including water and wastewater treatment, food and beverage processing, and pharmaceutical production.

Read more
Dynamic Pump

Dynamic Pump

Dynamic pumps use kinetic energy to move liquids, like water and oil, from a lower to a higher pressure.

Read more
Dynamic Blower

Dynamic Blower

Roots blowers operate by trapping a fixed amount of fluid or gas and expelling it against the system's pressure.

Read more
Dynamic Vessel

Dynamic Vessel

FRP is an updated composite material used for chemical plant appliances and equipment, including vessels and tanks.

Read more
Dynamic Flow Meter

Dynamic Flow Meter

Dynamic Flow Computers is one of the main global providers of advanced flow measurement solutions.

Read more